Project Summary
Client
Porte
Services
Geotechnical Engineering
Market
Property, Buildings and Facilities
Project Description
Origin at Simon Fraser University’s “UniverCity” campus is a five-storey residential community building, founded over a two-level underground parkade, that also includes a childcare centre and public art programs. Built under the new North American Green Zoning bylaws, Origin is 30% more sustainable than traditional construction.
Our Role
RAM’s geotechnical team was proud to be a part of the development team for Porte’s Origin residential development, and offered several services, including:
- Carrying out a subsurface site investigation comprised of auger drilling, dynamic cone penetration test (DCPT) soundings and failing head permeability tests;
- Providing hydraulic conductivity and seepage estimates to support storm water management design, including an infiltration gallery at the east side of the site;
- Designing a tied back shotcrete shoring system to support temporary excavation cuts;
- Groundwater assessment and modelling;
- Providing excavation shoring design;
- Conducting ongoing construction field reviews.